ZIPPY 1U REDUNTANT 120W PSU R1T2-5120V0H 215 X 106 X41.5 mm For Server FEATURES * TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 17MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 86%, MEASURED AT NOMINAL INPUT VOLTAGE 230 V AND FULL LOADING(+12V:10A). * LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC * REMOTE ON/OFF CONTROL * POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms * OVER POWER PROTECTION:110~150% MAX * OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.1V, +12V→12.8~15V * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB * SAFETY: MEET UL&CUL, TUV, CCC * WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL * THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS. OUTPUT WATTAGE 120W BEST SOLUTION FOR Server DIMENSION 215x106x41.5(mm) 8.46x4.17x1.63(inch) INPUT SPEC VOLTAGE: 90~264VAC FULL RANGE FREQUENCY: 47~63HZ INPUT CURRENT:2A (RMS) FOR 115 VAC 1A (RMS) FOR 230 VAC INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE 70A MAX. FOR 230 VAC PER MODULE DC OUTPUT SPEC Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple & Noise Max.[P-P] +5V 0 10 ±5% ±1% 50mV +12V 2 10 ±5% ±1% 120mV +3.3V 0 10 ± 5% ±1% 50mV -12V 0 0.3 ±10% ± 1% 120mV +5VSB 0.1 3 ±5% ±1% 50mV