Victron Dc to Dc Converter 12v to 24v 10 amp Galvanic Isolated
High efficiency
Using synchronous rectification, full load efficiency exceeds 95%.
IP43 protection
When installed with the screw terminals oriented downwards.
Input Voltage Range - 8 - 17v
Output Voltage - 20 - 30v
Efficiency - 88%
Continuous Output Current - 10 amp
Max. Output Current (10s) - 15 amp
Galvanic Isolation - Yes
Off Load Current - <100mA
Operating Temperature Range - -20 to +55 C (derate 3% per C above 40 C)
DC Connection - Screw Terminals
Maximum Cable Cross Section - 13mm AWG6
Weight - 1.3kg
Dimensions - 130 x 186 x 70mm
Screw terminals
No special tools needed for installation.
Victron Dc to Dc Converter 12v to 24v 10 amp Galvanic Isolated
High efficiency
Using synchronous rectification, full load efficiency exceeds 95%.
IP43 protection
When installed with the screw terminals oriented downwards.
Input Voltage Range - 8 - 17v
Output Voltage - 20 - 30v
Efficiency - 88%
Continuous Output Current - 10 amp
Max. Output Current (10s) - 15 amp
Galvanic Isolation - Yes
Off Load Current - <100mA
Operating Temperature Range - -20 to +55 C (derate 3% per C above 40 C)
DC Connection - Screw Terminals
Maximum Cable Cross Section - 13mm AWG6
Weight - 1.3kg
Dimensions - 130 x 186 x 70mm
Screw terminals
No special tools needed for installation.
Victron Dc to Dc Converter 12v to 24v 10 amp Galvanic Isolated
Installation
1. Select a cool, dry and ventilated area.
2. Connect the input supply cables. Note: the 12V and 24V input models have an internal input fuse (not replaceable). The 48V models do not have this fuse: external fuse required.
3. Optional remote on/off: replace the wire bridge on the green connector by a switch (switched current is less than 100mA), or remove the wire bridge and connect the right-hand terminal of the green connector to the battery plus with a switch (this could for example be the engine run/stop switch).
4. Adjustable output voltage: The default values are 12,2V, 24,2V or 48,2V, depending on the model. The output voltage can be set between approximately - 15% to + 25% of the default output voltage by turning the potentiometer. Turn counter clockwise to decrease the output voltage. Turn clockwise to increase the output voltage.
5. The output is overload and short circuit proof. The converters can therefore be connected in parallel, and can be used to float-charge a battery. (always adjust the output voltage before connecting in parallel or connecting a battery)
6. Connect the load. The converter is now ready for use.
All products come with manufacturers warranty with the length of warranty and terms and conditions being stipulated by the manufacturer. If no warranty period is stated then the default of 12 months will apply
Any warranty issues are to be directed back to us in the first instance and further instruction will be issued from there.
Returns are offered for up to 60 days from purchase. For 'change of mind' returns the purchaser is to cover the cost of the return